Resultado da pesquisa (2)

Termo utilizado na pesquisa água de coco

#1 - Effect of refrigeration at -1°C on spermatozoa quality of domestic cats

Abstract in English:

The objective of this study was to evaluate the sperm quality obtained of domestic cats by electroejaculation and recovery of the tail of the epididymis after cooling at -1°C and 4°C for 24 and 48 hours. Twenty-nine adult cats (2 to 6kg) were used. Sperm collection was performed by electroejaculation (EEJ), and after 48 hours, the cats were orchiectomized, and sperm sample was obtained from the vas deferens and epididymis tail (EPD). The samples were diluted in ACP-117® extender, and the sperm characteristics were evaluated at three different moments: when still fresh, 24 and 48 hours after cooling. In order to compare the two refrigeration temperatures, the first stage was to analyze if there was a difference between the harvesting techniques. After this, two experiments were conducted: in the first, sperm sample from 14 cats were used and the cooling was performed at -1°C; and in the second, sample from 15 cats were used and the sperm were refrigerated at 4°C. Sperm kinetics were evaluated by computerized analysis (CASA) and concentration by Neubauer chamber, spermatic morphology was evaluated by modified Karras staining, and membrane integrity was evaluated by eosin nigrosine. The results obtained were analyzed in R software, version 3.2.5 using the Mann-Whitney test for variables with abnormal distributions, considering significance at the level of 5%. In ejaculate samples, higher values of total morphological defects were observed after 24 and 48 hours of refrigeration at 4°C (P<0.022) compared to refrigeration at -1°C, using Friedman test. To quantify the decrease in sperm quality, parameter reductions were calculated among time points (F-24h/F-48h/24h-48h). In EPD samples, a greater reduction in sperm quality was detected after 24 hours of refrigeration at 4°C, both in motility and sperm kinetics and in the movement and velocity indices, compared to refrigeration at -1°C. Based on the results, it can be concluded that cooling of feline spermatozoa at -1°C for up to 48 hours was efficient in maintaining spermatic quality collected by EEJ and EPD, and it could be an alternative to spermatozoa cryopreservation in domestic felines.

Abstract in Portuguese:

O objetivo deste trabalho foi avaliar a qualidade espermática de gatos domésticos obtidos por eletroejaculação e recuperação da cauda do epidídimo após a refrigeração a -1°C e a 4°C por 24 e 48 horas. Vinte e nove gatos adultos (2 a 6kg) foram utilizados. A colheita de espermatozoides foi realizada por eletroejaculação (EEJ) e, após 48 horas, os gatos foram orquiectomizados, e as amostras espermáticas foram obtidas a partir do ducto deferente e da cauda do epidídimo (EPD). As amostras foram diluídas em ACP-117® e as características espermáticas foram avaliadas em três momentos distintos: fresco, 24 e 48 horas após a refrigeração. Para ser possível comparar as duas temperaturas de refrigeração, a primeira etapa foi analisar se havia diferença entre as técnicas de colheita. Após isto, dois experimentos foram conduzidos: no primeiro, espermatozoides de 14 gatos foram utilizados e a refrigeração foi realizada a -1°C; e no segundo, amostras de 15 gatos foram utilizados e os espermatozoides foram refrigerados a 4°C. A cinética espermática foi avaliada por análise computadorizada (CASA), a concentração por câmara de Neubauer, a morfologia espermática foi avaliada pela coloração de Karras modificada, e a integridade da membrana foi avaliada por eosina nigrosina. Os resultados obtidos foram analisados no software R, versão 3.2.5, utilizando o teste de Mann-Whitney para variáveis com distribuições anormais, considerando significância ao nível de 5%. No ejaculado, maiores valores de defeitos morfológicos totais foram observados após 24 e 48 horas de refrigeração a 4°C (P<0,022) em comparação com refrigeração a -1°C, usando o teste de Friedman. Para quantificar a diminuição na qualidade espermática, as reduções dos parâmetros foram calculadas entre os pontos de tempo (F-24h/F-48h/24h-48h). Na EPD, uma maior redução na qualidade espermática foi detectada após 24 horas de refrigeração a 4°C, tanto na motilidade e na cinética espermática quanto nos índices de movimento e velocidade, em comparação com a refrigeração a -1°C. Com base nos resultados, pode concluir-se que a refrigeração dos espermatozoides felino a -1°C, até 48 horas, foi eficaz na manutenção da qualidade espermático colhidos por EEJ e EPD, e pode ser uma alternativa para a criopreservação de espermatozoides em felinos domésticos.


#2 - Use of the ACP® and BTS extenders for cooling at 15°C white-lipped peccary (Tayassu pecari) semen

Abstract in English:

Knowledge about reproduction of white-lipped peccary is of great importance to assist with the conservation of this species and enable its rational use in captivity. This study aimed to evaluate the effect of ACP-103®, ACP-116® and BTS semen extenders on sperm viability during cooling of Tayassu pecari semen. Five ejaculates from four adult males were chilled. The animals were submitted to the protocols of sedation and anesthesia for semen collection by the electroejaculation method. After collection, the semen was macro- and microscopically assessed and diluted to reach 35x106 spermatozoa/mL in each of the three different extenders tested. The fresh-extended semen was packed in a BotuFLEX® thermal box to keep samples at 15°C for 24 hours. After cooling, the following semen parameters were analyzed: sperm motility, functional and structural integrity of sperm membranes, mitochondrial activity, chromatin condensation, and the thermoresistance test was performed. The parameters sperm motility, structural and functional integrity of sperm membranes, mitochondrial activity, and chromatin condensation were preserved after use of the extenders tested, and were similar to those of in natura semen (p>0.05). Curvilinear velocity (VCL) (p<0.05) was the only parameter with reduced values after cooling regardless of the extender used. The percentage of sperm with normal morphology was greater in samples cooled using the BTS extender (p<0.05). The ACP-103®, ACP-116® and BTS extenders can be used for the cooling and preservation of white-lipped peccary semen at 15°C for 24 hours.

Abstract in Portuguese:

Para auxiliar na conservação da espécie e permitir o uso racional do queixada em cativeiro é de grande importância o conhecimento sobre a reprodução da espécie. Objetivou-se avaliar o efeito dos diluidores de sêmen ACP-103®, ACP-116® e BTS na viabilidade espermática durante a refrigeração do sêmen do Tayassu pecari. Foram refrigerados cinco ejaculados provenientes de quatro machos adultos. Os animais foram contidos com auxílio de puçá e submetidos ao protocolo de sedação e anestesia para realização da coleta de sêmen pelo método da eletroejaculação. Depois da coleta, o sêmen foi avaliado macro e microscopicamente e diluído para atingir 35x106 espermatozoides/mL em cada um dos três diferentes diluidores testados. O sêmen diluído foi acondicionado em caixa térmica BotuFLEX® para manter as amostras a 15°C por um período de 24 horas. Depois da refrigeração, os espermatozoides foram avaliados quanto aos parâmetros de movimento espermático, integridade funcional e estrutural das membranas espermáticas, atividade mitocondrial, condensação da cromatina e teste de termorresistência. Os diluidores testados preservaram as características cinéticas, a integridade estrutural e funcional das membranas espermáticas, a atividade mitocondrial e a condensação da cromatina semelhante ao sêmen in natura (P>0,05). O único parâmetro que reduziu com o processo de refrigeração independente do diluidor utilizado foi a Velocidade Curvilinear (VCL) (P<0,05). Foi observado aumento do percentual de espermatozoides morfologicamente normais nas amostras refrigeradas em BTS (P<0,05). Os diluidores ACP-103®, ACP-116® e BTS podem refrigerar e conservar o sêmen de queixada a 15°C por 24 horas.


Colégio Brasileiro de Patologia Animal SciELO Brasil CAPES CNPQ UNB UFRRJ CFMV